Ikhwalithi ephezulu ye-9mm 2ml unyathela ingilazi ye-HPLC yomhlinzeki we-HPLC
I-AIJIREEN TEST TUBE TUBE yenziwa ngengilazi ye-borossilte, enganciphisa izinguquko ze-PH kanye nokungcola okungenziwa kufakwe ingilazi ye-soda lime. Ishubhu lokuhlola ingilazi lisetshenziselwa ukuhlaziya emazingeni okushisa aphezulu kunama-degree angama-130. Kwenziwa kusuka kwisitoreji selebhu ngezinhloso ezahlukahlukene futhi kungabamba cishe noma yini. I-Septa yenziwa nge-PTFE silicon rubber gasket, enomsebenzi oqinile wokubopha futhi ingamelana nokugqwala kwamakhemikhali ahlukahlukene. Isetshenziselwa ukuhlolwa kwamanzi emoyeni; amanzi amdaka ezimboni kanye nokuhlolwa kokulawulwa kwenqubo; kanye nokuhlolwa kwamanzi emvelo. Ama-tubetes asetshenzisiwe aqukethe i-sulfuric acid namanye amakhemikhali, ngakho-ke ama-reagents kumele aphathwe ngokucophelela. Okuqukethwe yipayipi kufanele kuchithwe ngokuya ngezidingo zabaphathi bendawo.
Ibhodlela le-1000ml reagentI-PolyPropylene imelana namakhemikhali kanye nezinto ezibonakalayo zokuzikhethela zamasampula abucayi be-PH abucayi, ukuhlaziya kwe-sodium noma okusindayo kwensimbi.Screw top headspace vialsI-8-425 vial inobubanzi obungaphandle kwe-8mm, usayizi ojwayelekile wezinhlelo ze-HPLC autosampler. Lolu sayizi olujwayelekile luqinisekisa ukuhambisana nobubanzi be-autosamplers nezinye izesekeli. Lezi zinhlaka zivame ukwenziwa kusuka kwikhwalithi ephezulu, ye-borossilte ingilazi noma ingilazi ye-1st hydrolytic-class ukuvikela ukusebenzisana phakathi kwesampula nesitsha. I-Aijiren Screw Thind Top Sampula Design Design ibonakala kalula ukusetshenziswa kwemali, ikakhulukazi ukusetshenziswa kwezinhlelo ezenzakalelayo zesampula, ngakho-ke lolu hlobo lwe-vial lubizwa nangokuthi i-autosampler vial. Futhi le vial yesampula iyahambelana kakhulu. Isampula ye-1.5ml yesampula esivame ukusisho ukuthi yi-2ML Volume Pampula ye-vial.
-Delile
ImikhiqizoXhumana nathiI-AIJIREN Micro VIALS & CAPS | Ukudla okuphezulu kwekhwalithi ephezulu ye-HPLC & GC
Yabelana:Ukufakwa okuncaneKukhona izicubu zengilazi nezinhlobo zepulasitiki ongakhetha kuzo, kanye nezinto ezihlukile zingakhethwa ngezigcawu ezahlukahlukene.
Ama-EPA Vials yilawo ahlangabezana nezidingo ze-US Environmental Protection Agency (EPA) yokuhlolwa kwezinto ezingcolisweni zemvelo ezingaba yingozi emanzini noma amasampula omhlabathi.
3) Ukulethwa okusheshayo, zonke izimpahla zingahanjiswa ngezinsuku ezingama-3-7. Imikhiqizo emikhulu ye-Qty isesitokweni kumakhasimende.
I-AIJIREN inikeza ama-vials amaningi ajwayelekile kanye namakhithi we-vial wesampula aguqukayo, isitoreji esihlanganisiwe nezinye izinhlelo ezingezona ze-chromatography.
4. Ingahlanganiswa ne-cap yebhodlela ne-septum. Ingasetshenziswa ngokushesha ukusindisa isikhathi sakho.
Isihlungi sesirinji
Ama-CAPS for isikulufu sontambo se-vials ayatholakala ngomgodi ovulekile wokusetshenziswa kwe-autosampler kanye nokungezwa okujwayelekile noma ngenhla eqinile yesitoreji sesampula. I-Teflone ne-Silicone Rubber noma i-silicone engcolile ye-ultra-emsulwa isetshenziswa njengezinto ezingavuthiwe ukuqinisekisa ukuthi i-Septa ayinobuthi; Ukuqinisekisa imisebenzi emihle kakhulu, ilungele ikakhulukazi i-chromatography yegesi, futhi iqinisekise ukuthi i-septum ayiweli ku-vial yesampula ngesikhathi senqubo yomjovo.
I-Aijiren Screw Tow Top Autosampler Vials Design ibonakala kalula ukusetshenziswa kalula, ikakhulukazi ukusetshenziswa kwezinhlelo ezenzakalelayo zesampula, ngakho-ke lolu hlobo lwe-vial lubizwa nangokuthi i-autosampler vial. Futhi le vial yesampula iyahambelana kakhulu. Isampula ye-1.5ml yesampula esivame ukusisho ukuthi yi-2ML Volume Pampula ye-vial.
Ama-headspace vials
I-9mm 2ml Ukunyathela kwe-HPLC Autosampler VIAL 100PCS egcwele ebhokisini elilodwa
2) Ithimba Lenkonzo Yezinsizakalo Zomthengisi
I-9mm Screw Congical Micro-VIAL yokuhlola i-chromatography ye-elebhu, usayizi we-micro-vial ngu-11.6x32mm.
I-5. Usayizi oqondile webhodlela uqinisekisa ukuphatha kahle nokulawulwa kwekhwalithi okuqinile. Qinisekisa ukungaguquguquki kobukhulu phakathi kwama-batches.
I-0.3ML Vials ene-Fire-Inpements efakwe kuqala yokuhlaziywa kwevolumu ephansi ye-Ultra-low. Inciphisa ukulahleka kwesampula (i-≤1μL Residue) futhi iyahambisana nezinhlelo ze-Agililent 6495c QQQ NS