HPLC\/GC Autosampler Vials & Bonded Caps | ND8, ND9, ND10, ND11 | Aijiren
Integram paro of 1ml putamen phialas cum 8mm PE plugs et pileos
Productum


Filter per applicationem - Reperio ius phialam tuam ad Methodum tuam
HPLC \\/ UHPLC Universale GC \/ GC-MS Volatiles PFAS-Free - EPA 1633 Trace Analysis \/ LC-MS Patefacio-Vials 4 mL Magnae Volumen Testa Vials - PE Plug
HPLC nobis GC - Vitare Electionem Overlap:ND9 (9-425) phialas cochleae vexillum pro injectione HPLC\/UHPLC autosampler iniectionem sunt. ND11 phialas phialas hermeticam aluminium obsignatum praebent clausuram retentionis volatilis in GC capitis spatio et GC-MS operabilibus — duo non convertuntur.
PFAS-Free Zonam - Strict terminus:EPA Methodus 1633 omnem fluoropolymer contactum prohibet. PFAS-Liberi sectio infra tantum PP phialas corporis cum septa fluoropolymer-liberorum continet. Nullae PTFE pilei lineales apparent in hac sectione sub quavis circumstantia.
Browse by Closure System - 11 Verified Product Pages
ND9 \/ 9-425 Short Thread

ND9 (9mm) Brevis Thread - 2026 Universal HPLC Standard

Corpus 12×32 mm, ± 0,2 mm colli concentricitas. Vices Agilent 1260\/1290, Aquae ACQUITAS, Shimadzu Nexera, Thermo Vanquish — non requiritur adaptor. Aperitio 40% maior est quam 8-425, acus eliminans deflexionem ad cyclum altum numerat.

USP Type I Borosilicate
9mm Brevis Thread Vials - Aperiens
Clarum & electrum. 1.5 mL \\/2 mL. Universalis convenit omnibus suggestis maioribus HPLC. Pre- gregato cum inserta vel planitie.
9mm phialam · 9-425 cochleae phialam · hplc vial
9mm Screw Caps — Bonded PTFE\/Silicone Septa
Septa chemica conjuncta pileo in corona - nulla impulsus-per periculum. Pre-rima pro automated iniectio. Facies acus PTFE latus impedit coringum.
9-425 cap· religata septa · hplc cap .
Verificatur compatible: Agilent 1260\/1290 Infinity II · Aquae ACQUITAS UPLC · Shimadzu Nexera SIL-30\/40 · Thermo Piscatoris Vanquish
ND11 \/ 11mm Crimp + Snap

ND11 Crimp & Snap - GC Volatile Aurum Standard & Summus Per HPLC

Crimp clausurae: aluminium testa mechanice comas septa - nulla relaxatio, nulla volatilis retrahitur calliditate. Requiritur ad spatium GC, GC-MS, et quaelibet matrix volatilis. Snap clausurae: instrumentum liberum pro summus throughput HPLC prep workflows.

USP Type I Borosilicate
1.5 mL ND11 Crimp Neck Vials
USP Type I. Serena & ambra. 11mm collum inuro. Pro GC, GC-MS, et in analysi capitis VOC. Agilent 7693A Thermo Trace GC compatible.
phialam inurtam · 11mm
11mm Aluminium Crimp Caps
PTFE\/ silicone septa. Aluminium putamen. Instrumentum crimping 11mm requirit. Maxima retentione volatilis - nulla septa relaxatio sub cyclo scelerisque.
inuro cap · 11mm cap · gc cap septa
11mm Snap Caps & Septa
Instrumentum liberorum clausurae. Velocissimo cyclo decapedo ad praeparationem HPLC summus throughput. Press-aptum annulum frangere cum PTFE\/silicone septa.
frangeretur cap 11mm frangeretur · frangeretur top phialam cap
GC nota: Crimp clausura facienda est matrices volatiles. Snap clausurae pro HPLC\/prep — pro GC analysi volatili non uteris.
ND8 \/ 8-425 Screw

ND8 (8-425) Screw - Legacy Platform & Imprimis Brand Compatibility

Retinuit Agilent MC\/1200 et eligere maiores aquae Foederis suggesta ante annum inaugurata 2018. 8-425 apertio 40% angustior est quam ND9 — acus contactum auget probabilitatem ad altum cycli rates. Pro omnibus systematibus a MMXVIII deinceps, ND9 specificatio commendatur.

Legatum Compatible
8-425 Cochleae Neck Vials — ND8, 1.5 mL
Purgare & electri borosilicate. 1.5 mL. linum 8-425. Ad Agilent 1100 \/1200 ac maiora suggesta quaerunt legata 8mm cochleae forma.
8-425 phialam · nd8 phialam · 8mm phialam cochleae
8-425 Caps & Silicone Septa
PTFE\/ silicone septa. Separate vel pre-conventi. Pro omnibus 8-425 cochleae phialam formats. Pre-rima praesto.
8-425 cap
ND10 \/ 10-425 Wide Opening

ND10 (10-425) Screw - Wide Opening for Microvolume Inserts & Manual Pipetting

Maximum acus dam alvi. Crux-contaminationis reduces periculum manualis pipetting. Specimen pro LC-MS\/MS bioanalysis cum speciminibus humili-volumi (DBS reconstitution, operarum microsampling). stamina 10-425 cum corpore 1.5 mL.

Bioanalysis Optimised
1.5 mL 10-425 Screw Thread Vials —
Maximized foramen diametri microvolumi inserta alignment. Crux-contaminationem reducit in manibus prep. Specimen pro DBS, micro-inserta, et opera bioanalytica.
10-425 phialam · nd10 phialam latam, phialam collum ·
10-425 Screw Caps — PTFE\/Silicone Septa
PTFE\/ silicone composita septa. Pre- rima. 10-425 Pro omnibus phialas collo patulo. Facies acu ptfe-iuctus, silicone fauore ad sanitatem.
10-425 cap
ND13 \/ 13-425 — 4 mL*

ND13 (13-425) — 4 mL Large Volume & Lava Solvent Vials

4 mL capacitatis cum filo cochleae 13—425. Usus ad lavandos receptacula solvenda, collectionis fractionis, et summus volumen specimen prep. Patet borosilicate. Compatible cum 13mm cap ecclesiis.

4 mL \\/ High Volume
4 mL 13-425 Cochleae Neck Vials — ND13
Patet borosilicate. 4 mL. 13-425 stamina. Lava phialas solvendas, collectionem fractionem, et volumen magnum specimen repositionis. Clara et electra consectetur.
4ml phialam · 13-425 phialam · nd13 phialam ?
Testa Vials Insert Vials

1 mL Testa Vials — PE Plug, Celeri Injection

8mm diameter PE obturaculum clausurae pro cyclo loading velocissimo sample. Designatur summus throughput prep and direct-injection workflows ubi cycli cochleae sequelae tempus est bottleneck. Phialam geometricam inserere cum fundo planae subtilitatis.

Princeps Throughput
1 mL Testa Vials — 8mm PE Plug
1 mL borosilicate. PE obturaculum pro celeri cap\/decap in high-throughput prep. insert-compatible. Specimen pro collectione fractionis et operiendo celeris operiendorum.
phialam vitream, phialam vitream inserere · phialam e obturaculum · 1ml phialam vitream
Regulatory Obsequium - PFAS-Free Dedicavit Zonam

PFAS-Free Vials & Closures — Methodus EPA 1633 \/ EPA 533 \/ EPA 537.1

Latin PTFE\/ silicone septa sunt materia PFAS praecursoris. Sub EPA Methodo 1633 (efficens Ianuarii 2026), omnes superficies contactus fluoropolymer a vasis sample PFAS eliminari debent. Haec sectio solum fluoropolymer-liberum consumables continet.

Prohibitum - non obsequium PFAS Vestigium Opus
PTFE\/ silicone septa - PTFE perfluorinated polymer
PTFE eidem cochlea tiaris in specimen contactum zona
Quaelibet phiala vitrea cum fluoropolymer efficiens
Compliant PFAS-Free configurationis
Polypropylene (PP) corpus phialae — fluoropolymer nulla
Polyimide vel summus puritatis silicone septa only
Background verificatur infra2.5 pptad XLVII scopum analytes
Meets EPA 533, 537.1 & Methodus 1633
Pars Numeri — PFAS-Free PP Vials & Closures:VP923 (pp cochleae phialas, 1.5 mL, 9-425), VP923A (succinum PP), cum caps polyimide septa. Producta haec nondum recensita sunt in copia online - commodo tuo rationem procuratori vel utereConsultatio technicaforma infra pro cursus sapien et disponibilitate.
Trace Analysis — Sub-100 ng\/mL Regula Electionis

Trace Analysis & LC-MS Vial Electio — 33 Expansio + Silanization

Ad quemlibet modum infra100 ng\\/mL, USP Type I, 33-expansio (Class A) borosilicata est facienda. Expansio coefficientis33×10⁻⁷\/°C— Infima metalli leaching omnium vitri commercii. Prohibet formationem adductam Na⁺\/Ca²⁺ in MS.

XXXIII Expansion - Type I Class A Serena
Amet pro:
Vestigium analysi infra 100 ng\/mL · LC-MS\/MS plenus-scan · basic medicamentum componit · interdum specimina · GTI\/ICH M7 opus immundum genotoxicum
Utere XXXIII, expansion ND9 phialas supra
Silanized phialas - TMCS Superficies amet
Superficies silanization (TMCS) deactivates circulos vitreos silanolos. Requiritur ad medicamenta alkalina, proteins principales, et residuum analysin pesticidium ubi adsorptio silanol causat apicem tendentem vel damnum analytici. Part N. VR913 — vide infra.
Materia Scientiae

33 Expansion vs

Ambae sunt USP Typus I borosilicatus. Recta optio determinatur per analyticam retrahitur gradu et photosensitivity - non per habitum vel disponibilitate.

USP Type I, Class A - XXXIII Expansion (Clara)
Trace & LC-MS Latin — Mandatorium infra 100 ng\/mL
Coefficiens33×10⁻⁷\/°C- lowest commercial speculum
Metal leachingLowest available - impedit adducts infra I ppb
Requiritur enimOmnes methodi vestigium, LC-MS, GTI\/IC M7, sub-ppb analysi environmental
Vitare, siAnalyte valde photolabile est - loco electri usus
USP Type I - 51 Expansion (Amber)
UV Photodegradation Protection — for Photolabile Analytes
Coefficiens51×10⁻⁷\/°C— Fe\/Mn dopant praebet UV scandalum
UV interclusioAbsorbet 300-500 nm — vitamins tuetur, pyrethrin pesticides, analytes fluorescent.
optimus forEPA 8270, ICH Q1B photostabilitas, medicamenta sensitiva levis, pesticides photolabiles
NotaPaulo altior contentus quam XXXIII-Ion metallum expansionem - non uti ad sub-C g \ / mL nisi photodegradation periculum overrides
Sententiae regulae:Usus33-expansion (patet) ;ad aliquem modum infra100 ng\\/mL, pro analytis fundamentalibus, vel cum MS adduct iones cura sunt. Usus51-expansion (amber) ;nisi photodegradation est primaria periculum et intentio est supra100 ng\\/mL. Ubi utrumque periculum est applicandum, utere silanized 33-expansio in levis interclusione secundarum fasciculorum.
Brief Catalogue — Part Numbers

Products Not Sed Recensiti Online - Interroga per Partem

Producta sequentia praesto sunt e catalogo fabricando nostro, sed in cinematographico nondum edito sunt. Referre Partem No. infra cum contingentes rationem vestram procurator.

Pars No. Descriptio Applicationem inquire
VP923 PP Screw Vials, 1.5 mL, 9-425, Serena PFAS analysis vestigium (EPA 1633) — corpus fluoropolymer inquire
VP923A PP Screw Vials, 1.5 mL, 9-425, Amber PFAS-free + photolabile analytes inquire
VR913 Silanized (TMCS) Vials, 1.5 mL, 9-425, Serena Medicamenta alcalina, proteins principales, residua pesticida - silanol deactivatio inquire
VR913A Silanized (TMCS) Vials, 1.5 mL, 9-425, Amber Silanized + photolabile: ICH Q1B photostabilitas fundamentalium compositorum inquire
VC-PI925 Polyimide Septa Caps, 9-425, PFAS-Free Claustrum pro VP923\/VP923A PP phialas - nulla contactus fluoropolymer inquire
Consultatio technica

Non certus Quod Vial aptat ratio tua?

Nostra applicatio fabrum phialas, commissuras, septa et materiales gradus ad certam tuam methodum aequant — HPLC, GC, vestigium LC-MS, PFAS, vel applicationes silanized. Etiam inquisitiones tractamus de Partibus Numeri inscriptis (VP923, VR913, et item catalogo extenso). Ante molem obligationis exemplaria praesto gratis.

Methodo-Level Ductu
Sancti cacumen radicis causa, phialam methodi congruens, septa lectio pro tua matrice et temperatura patens.
Pars Numeri audio
PP phialas, phialas silanized, polyimide septa, ornamentum conventus consuetudo — stipite et tempore plumbeo confirmata.
OEM & Bulk Supple
Morem print, notabant packaging, ornamentum conventus mixtum. Plena copia documentorum catenae ex D-pecie MOQ.
Request Free Sample Kit Contact Application Engineer


Inquisitionis
Inquisitionis