Maitiro Ekugadzirisa Zvakakodzera Sampuli muAutosamppler Vals

Sep. 20, 2023
Autosamuplers vanotamba chikamu chakakosha mumarabherari emazuva ano ne qualating sumo yekunyepedzera uye kupa otomatiki sumo yekusuma system. Chinhu chakakosha pane izvi chakakodzera kurodha samples mukatiautosamupler valspamwe nekugadzirira kukurukurirana kukuru; Mabasa ese ari maviri ane kukosha kwakakosha pamhando uye kuvimbika kwemhedzisiro kubva kuongororwa. Isu tiripo pano zvakakosha matanho, maitiro akanakisa, uye mazano ekuita kuti ave nechokwadi chekurapa panguvaKuenzanisira Kugadzirira\ / vial loading maitiro ane autosampleers.

CHIKAMU 1: Kugadzirira kuendesa samples


Asati atanga sampuli yekunyora, zvakakosha kuti ugadzire mamiriro akakodzera. Izvi ndizvo zvinoda kuitika:

1.1 Unganidza michina yako


Tanga nekuunganidza zvese zvinodiwa michina uye zvinhu:



Sampuli prep maturusi: Gadzirira nemapipi, syringes uye zvimwe zvidimbu zvinodikanwa zvezvishandiso kana zvasvika kune sampuke plu. Izvi zvinogona kusanganisira mapipi, syringes uye midziyo yekudhira kana ichishanda.

Chengetedza basa rekunyepedzera kuderedza njodzi yekusvibiswa.

1.2 Label yako vials


Asati atanga kuongorora, vial yega yega inofanirwa kuve yakanyorwa zvakajeka neruzivo rwakakosha zvinosanganisira kuzivikanwa kwechikuru, zuva uye chero imwe nzira yekuwedzera. Kunyora kunovimbisa kuturika pamwe nekudzivirira kusanganisa-ups panguva yekuongorora.

1.3.handsle samples nehanya


Nyatsobata samples kuitira kuti udzivise kusvibiswa uye kurasikirwa. Shandisa zvishandiso zvakakodzera, zvakadai sema pombi kana syringes, kana uchichinjisa samples mumavhuvhu; Dzivisa kubata chero nhengo kana mapundu emakwenzi neminwe sezvo izvi zvinogona kuunza mafuta eganda uye zvinosvibisa izvo zvinogona kuchinja.

1.4.Ita shuwa chaiyo sampuli vhoriyamu


Chaizvoizvo sampuli vhoriyamu yakakosha kuwana mhedzisiro yakavimbika. Shandisa zvigadzirwa zvakarongeka kuti zviyero zvakanyatsoyera uye kuendesa vhoriyamu yakakodzera mune vials; Gara uchigara uine yako yekuongorora nzira yakakurudzirwa sampuli vhoriyamu yakatarwa.

1.5 kuderedza mhepo mabhuru

Mabhumbi emhepo anogona kuita jekiseni rakawanda kwazvo. Kuti uderedze kuumbwa kwavo:

Dzivisa zvine simba kudzokorora samples mu vial. Zadza zvishoma nezvishoma uye mushe, uchiri kuibaya zvinyoro-nyoro kuti ubvise mumhepo mabhuru.
Kamwe samples dzakatakurwa mumakamuri, simbisa ivo vakachengeteka vachishandisa zvakakodzera caps uye Septa. Zadzisa chisimbiso chemahara chichabatsira kudzivirira sampu yemumuenzaniso kana kusvibiswa; Paunenge uchishandisa Crimp Caps Shandisa chishandiso zvakananga nebasa iro rakachengeteka kuvharwa.
Ongorora mune-kudzika kwezvinhu zveHPLC Sampuli mune ino chinyorwa chinodzidzisa:HPLC yemuenzaniso yekugadzirira mhinduro dzemhedzisiro yakanaka

CHIKAMU 2: SAMPLE PLAP TOLPNIQUES


Kubudirira kwekuenzanisira kunowanzo kugadzirira kazhinji kuchinjika kuongororwa kwakarurama. Zvichienderana nenzira yako yekuongorora, samples dzinogona kunge dzichida kuti dzifadzwe, kana dzikangoita kana kusarudzika zvisati zvatevedzera manhamba akakurudzirwa.

CHIKAMU 3: Kuisa samples mu autosamppler vials


Zvino kuti samples dzako dzakagadzirirwa, inguva yekuvarongedza zvakarongeka mu autosamupler:

3.1 Store Vals zvakanaka

Kana kuongororwa kwako kwacho kunoda nguva yekumirira isati yasvika pakurongeka

3.2 Ronga vakunda vako

Gadzira iyo inoshanda system yekuronga yako vials. Varongedze zvine musoro, uye funga nezvekushandisa vial racks kana trays kudzivirira kusanganisa-ups panguva yekuongorora.

3.3 ita system yakakodzera cheki


Pamberi pekumhanyisa samples, inopa zano yekuitisa system yakakodzera cheki. Izvi zvinovimbisa kuti iyo quinoupler iri kushanda sezvakarongwa uye kuti samples yako yakatakurwa mukati mazvo.

3.4 Vial Kuenderana Kuedza Kuedza (VCT)


Samples dzakasiyana dzinoda madhiri chaiwo; amber kanaVarume vakajekaInogona kukwana apo vials yakasarudzika yakagadzirirwa zvakananga kuti zvikumbiro zvakati zvingave zvichidikanwa. Kuchenjera kuratidza kuwirirana kwemakungwa ako nemhando yemhando mbiri uye yekuongorora nzira kuitira kuti udzivise zvinhu zvingangoitika panguva yekuongorora.

CHIKAMU 4: Post-mutoro uye kuongororwa


4.1 chengetedza uye wakachena autosamupler zvikamu


Kuti urambe uchikoshesa autosupplerr performance, gara uchichengetedza uye kuchenesa zvikamu zvaro - kusanganisira sampula probes, syringes, uye jekiseni rezvikwata. Zvasara kana zvakasvibiswa zvinogona kukanganisa chinjana chekutamisa zvinotungamira kune mhinduro isiriyo; Kutevera kurudziro yekugadzira uye kumisikidza chirongwa chekugadzirisa.

4.2 Gwaro maitiro ako

Chinhu chakakosha chebasa rekutambisa riri kuramba uchiwedzera zvinyorwa. Ive nechokwadi chekubatanidza chero kutsauka kana nyaya dzakasangana panguva yemuenzaniso kurodha mugwaro iri, izvo zvichashanda seyakawanikwa kugadzirisa dambudziko uye kuongororwa mukuongororwa kwekuongorora.

4.3 Kugara uchiita zvinhu zvekusimbisa zvinhu zvinofanirwa kuitwa


Simbisai mukana wekunyora Chero kutsauka kubva pamisungo inotarisirwa kunofanira kufambisa kumwe kuongorora uye kururamisa chiito kutorwa nekukurumidza.

4.4 kugadzirisa nyaya nekukurumidza


Kugadzirisa matambudziko asingatarisirwi kana mhedzisiro isingaenderane nekukurumidza kana ikakamuka, senge zvisingatarisirwi, sekusatarisirwa semienzaniso inotakura matambudziko sekuvhara kana kusvibiswa izvo zvinokanganisa hunhu. Nekutora nzira yakarongeka yekugadzirisa dambudziko, matambudziko achaziviswa nyore uye anogadzirwazve nekukurumidza.

Kushandisa hunyanzvi hwekutanga kugadzirira uye kurodha autosamppler vials kiyi yekugadzira chaiyo uye yakavimbika yekuongorora mhedzisiro. Nekuomerera kune zviito zvakanakisa, uye nekuchengetedza michina, uye kuongorora nyaya dzenyu, iwe unokwanisa kupa zvizere


Tsvaga mhinduro dzemakumi mashanu emhando dzeHPLC VID mibvunzo mune ino yakakwana uye inodzidzisa chinyorwa:50 Mibvunzo inowanzo bvunzwa paHPLC vials