.webp)

Our own laboratory releases each batch, so the certificate, the dimensions and the bonding force are measured on the goods you receive — not copied from a supplier's file.
Four documents ship with every order. The raw data behind them is available on request, including the individual bonding force readings for the batch in your box.
Four documents, issued by our own laboratory for the specific batch in your shipment — not templates, and not the raw material supplier's paperwork.
| Document | What it contains |
|---|---|
| Certificate of Analysis | Batch number, tested parameters, measured values, specification limits and the pass or fail verdict — signed and dated by the releasing analyst. |
| Dimensional Report | Body diameter, height, neck finish and concentricity measured against specification. Issued per product type, re-verified per batch. |
| Material Declaration | Glass type, septa compound, cap polymer and surface treatment, stated explicitly so your method validation does not depend on assumptions. |
| Bonding Force Report | Pull test on the assembled cap-and-septa unit, with every individual reading. ≥ 40 N is the release limit. |
Performed in our own laboratory. Items marked "on request" are available but not released with every batch — ask for them with your quotation.
| Parameter | Method | Specification | Frequency |
|---|---|---|---|
| Bonding force | Tensile pull, in-house method | ≥ 40 N on assembled unit | Every batch |
| Septa hardness | Shore A, ASTM D2240 / ISO 7619-1 | 45–60 Shore A by grade | Every batch |
| Septa thickness | Micrometer | 1.0 / 1.5 / 3.0 mm | Every batch |
| Vial dimensions | Micrometer and vision measurement | 12 × 32 mm body, neck concentricity ±0.2 mm | Every batch |
| Visual and particulate | Light table inspection in cleanroom | No visible particulate or deformation | Every batch |
| Glass hydrolytic resistance | USP <660> / ISO 719 | Type I borosilicate | On request |
| Temperature resistance | Oven exposure with dimensional check | −60 °C to 200 °C, septa grade dependent | On request |
| Total fluorine (PFAS screening) | EN 14582 / IEC 62321-3-2 | Below detection limit, fluorine-free grades | On request |
| Extractables and leachables | LC-MS / GC-MS, method dependent | Project-specific | On request |
Three levels. The right one depends on your detection limit, not on your budget.
| Grade | What it means | Typical use |
|---|---|---|
| Standard | Production in 100,000-class cleanroom, visual inspection, standard packaging | Routine HPLC and GC, general sample storage |
| High-clean | Additional cleaning and handling controls, reduced particulate and extractable load | Trace analysis, LC-MS, method development |
| TOC grade | High-clean plus low-bleed closure, controlled for organic carbon contribution | 40 mL TOC, purge-and-trap, VOA |
| Item | Detail |
|---|---|
| ISO 9001:2015 | Quality management system certified. Scope covers design and manufacture of chromatography vials, closures and filtration products. |
| Cleanroom | All product contact operations run in a class 100,000 cleanroom, including assembly and packaging. |
| Batch traceability | Every carton carries a batch number that resolves to raw material lot, production date, operator shift and release record. |
| Third-party testing | SGS and other accredited laboratories used for total fluorine and customer-specific validation projects. |
Send the part number and the parameters your method requires — we will return the COA, dimensional report and material declaration for the current batch.
Direct contact: Boonemi@aijirenvial.com · Tel +86 183 3883 2256