Sterile Syringe Filters, 13/25/33mm, 0.22 & 0.45µm | Aijiren
Home / Products / Syringe Filter / Sterile Syringe Filters

Sterile Syringe Filters

Individually packed sterile syringe filters for critical applications. 13, 25 and 33 mm diameters in Nylon, PVDF, PTFE and PES, with 0.22 µm and 0.45 µm pore sizes.

MembraneNylon / PVDF / PTFE / PES
Pore size0.22 / 0.45 µm
Diameter13 / 25 / 33 mm
PackingIndividually wrapped, 100/pk

Why Sterile Syringe Filters

A sterile syringe filter is used when the filtrate itself must be sterile: media preparation, buffer sterilisation, cell culture work and any sample that cannot be autoclaved after filtration.

Each filter is individually wrapped and sterilised, so the packaging — not the filter — is what you check before use. A damaged sachet means the filter is no longer sterile, regardless of the membrane.

How to use a sterile syringe filter

Five steps that keep the filtrate sterile.

1. Check the pack

Confirm the sachet is sealed and undamaged before opening.

2. Connect

Wipe the syringe tip with 70% alcohol, then attach the filter luer-lock.

3. Prime

Push 1–2 mL through to wet the membrane and clear air.

4. Filter

Fill the receiving vessel slowly; discard the first few drops.

5. Single use

Do not reuse or resterilise — the membrane and housing are one-time items.

Specifications

26 part numbers

Jump to membrane: Nylon · PVDF · PTFE · PES

Part No.DiameterPore sizeMembranePcs/Pack
FN1322S13 mm0.22 µmNylon100
FN1345S13 mm0.45 µmNylon100
FN2522S25 mm0.22 µmNylon100
FN2545S25 mm0.45 µmNylon100
FN3322S33 mm0.22 µmNylon100
FN3345S33 mm0.45 µmNylon100
FF1322S13 mm0.22 µmPVDF100
FF1345S13 mm0.45 µmPVDF100
FF2522S25 mm0.22 µmPVDF100
FF2545S25 mm0.45 µmPVDF100
FF3322S33 mm0.22 µmPVDF100
FE1322IS13 mm0.22 µmPTFE (hydrophilic)100
FE1345IS13 mm0.45 µmPTFE (hydrophilic)100
FE2522IS25 mm0.22 µmPTFE (hydrophilic)100
FE2545IS25 mm0.45 µmPTFE (hydrophilic)100
FE3322IS33 mm0.22 µmPTFE (hydrophilic)100
FE3345IS33 mm0.45 µmPTFE (hydrophilic)100
FE2522S25 mm0.22 µmPTFE (hydrophobic)100
FE2545S25 mm0.45 µmPTFE (hydrophobic)100
FE3322S33 mm0.22 µmPTFE (hydrophobic)100
FE3345S33 mm0.45 µmPTFE (hydrophobic)100
FS1322S13 mm0.22 µmPES100
FS1345S13 mm0.45 µmPES100
FS2522S25 mm0.22 µmPES100
FS2545S25 mm0.45 µmPES100
FS3322S33 mm0.22 µmPES100

Features

Individually packed

Each unit wrapped and sterilised.

Four membranes

Nylon, PVDF, PTFE (hydrophobic and hydrophilic) and PES.

0.22 µm sterile grade

Bacteria-retentive for media and buffers.

Luer connections

Luer-lock inlet, luer-slip outlet.

Batch traceability

Lot number printed on each sachet.

13–33 mm

Sized for 1 mL to 100 mL samples.

FAQ

Sterile or non-sterile — which do I need?

Choose sterile when the filtrate must remain sterile (media, buffers, cell work). For routine HPLC sample prep, non-sterile filters are sufficient and cheaper.

What does 0.22 µm mean for sterility?

0.22 µm is the standard bacteria-retentive pore size used for sterile filtration; 0.45 µm removes particles but is not sterile-grade.

Can I filter protein solutions?

Yes. Use PVDF or PES, which bind less protein than nylon. Pre-wet hydrophobic PTFE with alcohol first.

How are they packed?

Individually wrapped, 100 pieces per pack, with the lot number on each sachet.

Is there a non-sterile version?

Yes — see the non-sterile PTFE, PVDF, PES, Nylon and MCE pages for the same diameters without individual packing.

Customer FAQ

Certificates, MOQ, quality control, after-sales support and lead times.

What certificates do you have?

Aijiren is certified to ISO 9001:2015 by SGS, ensuring controlled manufacturing processes and stable, fully traceable product quality.

With continuous investment in R&D and multiple independent patents, we deliver high-performance and reliable consumables to laboratories worldwide.

Some of the certificates of Aijiren are displayed here:

What’s the MOQ? Do you accept small orders?

Aijiren supports both standard and small batch orders. While MOQ varies by product type, we are happy to accommodate smaller quantities for trial, testing, or special projects. Please contact us for specific requirements.

Is the quality guaranteed?

All Aijiren products undergo random sampling and multiple in-house quality tests. Each batch is fully traceable, ensuring stable and reliable performance for your laboratory work.

What kind of after-sales support does Aijiren provide?

Aijiren provides practical after-sales support:

Returns & replacements — any product affecting use or sales can be returned or replaced.

Technical support — assistance with product use and troubleshooting.

Order tracking & follow-up — we monitor shipments and follow up to ensure timely delivery.

Dedicated contact — a direct contact for after-sales inquiries.

This ensures your laboratory work runs smoothly with minimal disruption.

How long will it take for orders?

The delivery time depends on the order quantity and whether customisation is required:

In-stock products — shipped within 3–7 days after payment.

Standard bulk orders — shipped within 2–4 weeks.

OEM/ODM customised products — shipped within 3–5 weeks, depending on mould, logo, colour and packaging.

Aijiren has automated production lines and a 100,000-class cleanroom, ensuring stable lead times and reliable supply.

Factory Tour & VR

Walk through our workshops and 100,000-class cleanroom — six stops are interactive 360° tours.

Virtual tour hosted by Linked-Reality. Prefer a live walkthrough? Ask us for a video call during your next audit.

Need a quote or a sample?

Tell us the size, material and pack size — we reply within one working day.

Email boonemi@aijirenvia.com
Inquiry