For Syringe Filters you Will Reused?
News
Home > News
categories
INQUERY

For Syringe Filters you Will Reused?

Aug. 3rd, 2022
We do not recommend a reusable disposable Syringe Filter. Because there is a possibility of cross-contamination with repeated use. Once a problem occurs, it is necessary to check whether the sample is contaminated. This will result in higher costs. 
 
A Syringe Filter is generally used to remove particles from a liquid sample prior to some kind of analysis to avoid damage to equipment (e.g. ion chromatography, ICP, etc.) They are relatively affordable, can be used for small volumes, and avoid the difficulties involved in using Buckner filter setups or similar.
 
Syringe filters are generally used to remove particles from a liquid sample prior to some kind of analysis to avoid damage to equipment 
The main two types of filters are either those where you can recover your sample or not. The majority of syringe filters used do not allow you to reclaim the solid. They are often used before analysis to remove any solid, undissolved, material. Other, filter holder (in-line) types allow you to regain your filter.

Wholesale 0.22um micron syringe filters supplier
 

Cleaning of Syringe Filter

 
When cleaning the syringe filter, the distilled water is firstly pumped repeatedly with a needle tube, followed by ultrasonic for about 20 minutes, then soaked in distilled water for more than 5 hours, then removed and dried at about 40 degrees. Don't bake the gaskets, just let them dry naturally.
The cleaning and disinfection of the micron Syringe Filter after use is the same as that of other high-pressure plastics, but polyethylene cannot be high-pressure.
 
A. The water is washed ten times and dried. We also use the gasket for drying. The discoloration has little effect. In general, set the oven temperature is usually set at 56 degrees because EDAT is often needed to be dissolved;
The cleaning and disinfection of the micron syringe filters after use is the same as that of other high-pressure plastics
B. Soak in 1% hydrochloric acid is soaked overnight (less than 6h);
C. Water is repeatedly washed 10 times and then distilled water is washed twice, then the filter membrane can be installed under high pressure or dried for later use.

buy cheap syringe filter manufacturer online
 

Disinfection of Syringe Filter

 
Do not soak the Syringe Filter cap in acid liquid, boil it for 20 minutes or soak the cap in NaOH for 6-12 hours. Install two filter membranes before packing. We need to pay attention to the membrane up or downside and make sure it’s upside when the filter membrane is installed. Slightly loosen the screw, place it in an aluminum box, sterilize it for 15 pounds for 30 minutes in a pressure cooker, and then dry it for later use. Please note that, when taking it out, tighten the screw immediately.
 
Do not soak the syringe filter cap in acid liquid, boil it for 20 minutes or soak the cap in NaOH for 6-12 hours.
Soak the Filter Membrane in three steamed water for at least half an hour at high pressure. In addition, do not tighten the lab syringe when installing. The membrane has both sides, smooth face down, and rough face up so that the filters will save effort. Good for immediate use after high pressure. The filter membrane is good do not want secondary high pressure.
 

Composition of Filter Memrbane

The Filter Membrane is generally put in two layers. The upper membrane was 0.4 micron, the lower was 0.22 micron, and the two layers were 0.22 micron. Put the PTFE syringe filter into the PES filters after soaking for 10~20 minutes. After it is packed, wrap the syringe filters in a cloth and sterilize them. Note that the membrane should be perpendicular to the ground so that it will not break even at high pressure. The autoclavable syringe filter should be soaked in distilled water for more than 3 hours or overnight, and then placed on the syringe filter screen, smooth face up. When you twist the syringe filters, you can just twist the airtight.

0.45um PTFE syringe filter for HPLC analysis
 
If you cannot tighten the Syringe Filter, lift the vent switch and wrap the outlet with sulfate paper. Wrap the strainer in kraft paper. The syringe filters should be tightened when using, but the force should be evenly applied. Soak in dilute hydrochloric acid for about an hour.
wholesale cheap syringe filter from China
 
After the tap water is rinsed, soak in the double steam water overnight. After drying, moisten the Syringe Filter Membrane face up, then stick it on and twist the double steam water, but do not tighten it too tightly. Fetch, then dry, and it's ready to use. Note that if the syringe filter is not used up at one time, do not disinfect it twice to prevent the filter membrane from breaking.
 
We advise against reusing them, since fine particulates that are too small to be visible to the naked eye may cause cross-contamination and compromise your results.
More discussion about Syringe Filter is welcomed.
Inquiry
5-30% Discount!
How Much Discount You Can Get?
Answer Just One Question
Attention: Discount Only effective before April 1st 2024